Equipment
Refine Assets By
Selected Filters
Search In These Assets
Category:
Include all
Manufacturer
Include all
Condition
Include all
Motor HP
Include all
Material
Include all
Heat Exchanger
Include all
TEMA
Include all
All Assets from Category 'Watertube'
2 Results
Sort:
Relevance
Refine Assets By
Selected Filters
Search In These Assets
Category:
Include all
Manufacturer
Include all
Condition
Include all
Motor HP
Include all
Material
Include all
Heat Exchanger
Include all
TEMA
Include all
Watertube Boiler 250,000 #/hr
Asset ID: 2349
Available: 1
### Cleaver Brooks Industrial Watertube Boiler 250,000 lbs/hr superheated steam ###
- Boiler model NB-801D-125-550-AL-LH, serial CP-4582
- NEW, never installed
- D-type watertube style
- Pressure 420 psig operating pressure (superheated, temp 650F +/- 25). Superheated steam
- Natcom LoNOX Burner, natural gas. Gas train included. Burner model NCB-330-68A-000-S10-000
- Stack included - 3 sections
- Economizer, ECO, Inc. vertical 7.5 ft dia x 20 ft tall
- Controls - 2 plc's + burner management + combustion controls
- Includes SCR for emissions reduction
- Under nitrogen purge with desiccant in furnace area
Removed and stored - ready to load. See additional information in document links
Asset ID: 2349
Available: 1
Watertube Boiler 250,000 #/hr
### Cleaver Brooks Industrial Watertube Boiler 250,000 lbs/hr superheated steam ### - Boiler model NB-801D-125-550-AL-LH, serial CP-4582 - NEW, never installed - D-type watertube style - Pressure 420 psig operating pressure (superheated, temp 650F +/- 25)....
Watertube Boiler 90,000 lbs/hr
Asset ID: 2116
Available: 1
### Watertube Boiler with Economizer 90,000 #/hr Natural Gas ###
Victory Natural Gas Watertube Boiler Type O, Voyager Series VS-5-78SP SH. Capacity 90,000 lbs./hr saturated steam at 800 psig (design pressure 950 psig) ASME Nat'l Bd # 589.
- Economizer
- Feedwater System
- Stack 50 feet
- Electrical and PLC control systems.
With feedwater temperature 227 Fahrenheit to economizer inlet. Complete economizer system. Furnace Radiant Heating Surface 889 Sq. Ft, Boiler Convective Heating Surface 6,455 Sq. Ft., Total Heating Surface 7,344 Sq. Ft. Superheater surface is 980 sq. ft. Drums Submerged arc automatic welded and stress relieved with radiographed welded seams and tubes are rolled and expanded into the drum.
Drum material is SA-516 Gr. 70. Mud Drum is provided with a 12” x 16” hinged manway access in each drum head. Steam Drum is provided with a 12” x 16” hinged manway access in each drum head. All tubes enter the drum radially with full parallel bearing through the drum plate and all tubes are full diameter with no swaging.
All tubes are full diameter tubes with no swaging.