Steam Turbine Gen Set 7 MW
Asset ID: 2117
Available: 1
### GenSet - Howden 7MW Steam Turbine with AC Generator, 50/60 Hz. Model TWIN-CA 56 ###
**GenSet Rating 7 MW at 13.8 kV 60 Hz**
Used less than a year - still under power
***Turbine***
- Manufacturer Howden. OEM: Siemens Turbomachinery Equipment / TD Power systems Series SST-110.
- Operates on 900 F superheated steam at 800 psig
- Provides process steam at 375 F at 46 psig.
***AC generator***
- Generator is a Brushless AC generator with an AC exciter and rotating rectifier mounted on a common shaft.
- Continuous rated output kW / kVA 7000 / 8750
- Speed in (rpm) 1800
- Voltage (Volts) 13800
- Full load current (Amps) 366
- Frequency (Hz) 60 Hz 3 phase
- Power factor 0.8 (Lag)
- No. Of poles 4, insulation Class F
- Enclosure Main: IP 54
- Cooling System Main: IC 81W
- Bearings Two nos. sleeve Bearings
- Bearing oil feed system Forced Lubrication
Used less than a year and is still under power.

Asset ID: 2117
Available: 1
Steam Turbine Gen Set 7 MW
### GenSet - Howden 7MW Steam Turbine with AC Generator, 50/60 Hz. Model TWIN-CA 56 ### **GenSet Rating 7 MW at 13.8 kV 60 Hz** Used less than a year - still under power ***Turbine*** - Manufacturer Howden. OEM: Siemens Turbomachinery Equipment / TD Power systems Series SST-110....

Generator Gas Dryer and Analyzer
Asset ID: 8881
Available: 1
### GAS STATION™ From E/One ###
**GAS STATION is a new modular approach to gas control and monitoring for hydrogen-cooled generators**
The E/One Gas Station is a modular approach that combines monitoring and control systems onto a single skid
**MODULES**
- Generator Gas Analyzer - GGA
The Generator Gas Analyzer (GGA) continuously analyzes generator cooling gas during normal and purge operations to ensure optimum purity levels and maximum operational efficiency. ssembly # HD0135G01. Serial # GS 0109. Single phase, 120 VAC, 30 Watts, 50/60Hz. Thermocnductivity measurements designed for gas flow rates fro 100 to 700 cc/min. Triple-range sensor/analyzer that provides continuous monitoring of gas purity during all phases of generator operation.
- Generator Gas Dryer - GCD
eOne's Generator Gas Dryer (GGD) removes contaminants from the hydrogen cooling gas through all phases of generator operation. Assembly # DD0125G07. Serial # GGD 0112. Single phase, 480 VAC, 2.4 KW, 50/60 Hz. Dual-chamber system continuously dries and recirculates generator cooling gas

Asset ID: 8881
Available: 1
Generator Gas Dryer and Analyzer
### GAS STATION™ From E/One ### **GAS STATION is a new modular approach to gas control and monitoring for hydrogen-cooled generators** The E/One Gas Station is a modular approach that combines monitoring and control systems onto a single skid **MODULES** - Generator Gas Analyzer - GGA The....

CHP Turbine GenSet with HRSG 12 MW
Asset ID: PK-1500
Available: 1
## Solar Turbine GenSet 12 MW with ABB Generator and Rentech HRSG ##
## CHP Combined Heat and Power System ##
- Turbine and Generator were designed with breeching for a HRSG although not this specific HRSG. Ratings match and some work may be needed on breeching to mate up but this is a very close match.
- Approximate size of turbine GenSet is 60 ft long x 11 ft wide x 11 ft high (does not include the HRSG)
- All pieces are NEW, old stock and never installed. (GenSet 2021, HRSG 2024). Stored in protected warehouses
- More detail is available on this system - ask for an invitation to our Virtual Data Room (VDR)
***Solar Turbine***
- Manufacturer Solar Turbines, Model Titan T-130
- Operates on low BTU syngas fuels, as low as 500 BTU/cu ft
- This turbine is specially designed to handle gas at lower BTU values but can be modified to run on pipeline natural gas
- In enclosure with inlet filters & exhaust breaching for HRSG (no exhaust stack or diverter valve).
***ABB Generator***
**GenSet rating 12 MW at 13,800V, 3ph, 60 hz**
- Continuous rated output kW / kVA 14,986
## Rentech Duct Fired HRSG System (Heat Recovery Steam Generator) ##
- Model Waterfall Type "O"
- Rated at 200,000 pph at 400 psig saturated steam with economizer (can also run at 200 psig)
- Designed for feedwater flow 400 gpm at 439 psig and 228F
**INCUDES** (also see pdf list in link)
- Natural gas duct burner system and fuel skid with gas train and flame supervision, rated at 136 MMBTU/h
- Steam Generator System (HRSG) Evaporator. "O" type tube arrangement with steam drum and mud drum, 2" tubes
- Bypass stack 50 ft x 76" diameter
- Exhaust stack 50 ft x 76" diameter
- Economizer - finned tube single pass
- Boiler Control System: BMS - plc controlled burner management system, CCS - combustion control system, HMI touch screen, Allen Bradley plc and HMI
- Interconnecting duct work
- Ladders & Gratings
**System has been completed and is now stored in protected warehouse (never has been used)**

Asset ID: PK-1500
Available: 1
CHP Turbine GenSet with HRSG 12 MW
## Solar Turbine GenSet 12 MW with ABB Generator and Rentech HRSG ## ## CHP Combined Heat and Power System ## - Turbine and Generator were designed with breeching for a HRSG although not this specific HRSG....

Generator Set 703 KW
Asset ID: 7880
Available: 2
### CAT G3516, 703 KW Cont. NG Generator Sets Qty (2) - SOLD as a LOT ###
- Natural gas fired
- Cain exhaust heat recovery exchangers for hot water. (Rectangular Tube Heat Recovery Series - RTR)
- Mufflers
- Engine: 3516, S/N: CTL00524 & CTL00528, Arrg. #199-2600, 1200rpm
**Kato Engineering Synchronous AC Generator**
Model: A272520001, S/N: 15162-01 & 02, Code: C062-6480
KW: 703 CONT, 3Ph, 6-Wire, 60 Hz, KVA: 781, P.F.: 0.9, RPM: 1200, Voltage: 7200/12470, Amps: 43
Temp Rise: 105 Deg C, Ambient: 40 Deg. C, Ins. CL: F
Exciter Field Amps: 2.8, Field Volts: 100, PMG Volts: 240, PMG Hz: 120
2-bearing generator
Does Not Include: Controllers or Radiators.
Gen. #1: 55,253 Hours on 2/21/17
Gen. #2: 58,980 Hours on 2/21/17